Skip to main content

Eight common roto print defects, what causes them, and how to correct them on press.

This guide sets out the eight print defects our technical team is called out to most often in rotogravure production. Each entry describes what the defect looks like on the printed web, lists the probable causes in the order worth checking them, and gives the corrective action.

If you still have questions our technical service team supports customers across Europe, the Middle East and Africa directly on site.

Before you change anything: work the variables in order

Changing three settings at once tells you nothing about which one fixed the problem. When a defect appears mid-run, isolate it in this sequence:

  1. The ink. Check viscosity against the job standard first. Then check solvent balance and drying speed, resolubility, contamination, and how long the ink has been circulating. Confirm the ink system matches the substrate and the application.
  2. The transfer. Cylinder cell depth and geometry, chrome quality and surface condition, cylinder balance and concentricity. Doctor blade type, angle, pressure, parallelism, cleanliness and blade support.
  3. The machine. Impression roller pressure and durometer; web tension through printing and rewind; oven temperature and air velocity; chill roll function and temperature relative to the dew point; electrostatic assist.
  4. The substrate. Corona treatment level and age of the film, surface cleanliness, thickness tolerance, temperature on entry to the press, wetting behaviour.

Record what you changed and what happened. A defect log turns one operator's fix into plant-wide knowledge. 

Potential Issues

What you see:

The ink does not adhere sufficiently to the substrate and can be removed easily, typically failing the tape adhesive resistance test.

Adhesion failures are the most commercially serious defect on this list, because they often pass visual inspection at the press and are only discovered downstream after lamination, filling or in the customer's hands. Treat ink system compatibility and surface energy as your first two checks. 

lack of ink adhesion with error
With Error
lack of ink adhesion correct image
Without Error

Start here:

Μeasure the film's surface tension before adjusting anything on the press. Corona treatment decays with time in storage, and an under-treated or aged film will defeat every other correction you make.

Potential issues & solutions

Potential issue
The surface treatment is inadequate.
Recommended solution

Evaluate the film's treatment level. Adjust the machine's refreshing treatment and consider using fresh film. Add adhesion promoter at the ink according to ink supplier instructions

Potential issue
The ink is not drying.
Recommended solution

Introduce faster evaporating solvents, and increase fresh air circulation and heat supply.

Potential issue
Insufficient adhesion observed between different colors.
Recommended solution

This may happen if two distinct ink systems are printed consecutively. Verify that the ink layering is appropriate.

Potential issue
The film surface is contaminated.
Recommended solution

Apply a suitable primer or corona refresh before commencing printing, or switch to a more appropriate film batch.

Potential issue
The printing material is not compatible with the ink.
Recommended solution

Verify that the appropriate ink system for the specific materials is being used.

What you see:

Τhe ink adheres to the reverse side of the film and causes damage when the substrate is unrolled.

Blocking is a heat-and-solvent problem. It is nearly always the result of ink that has not fully released its solvent before the web is wound, or of a reel that is wound too tightly, too warm, or both.

blocking with error image
With Error
blocking correct image
Without Error

Start here:

Μeasure the web temperature at the rewind. If the film is going into the reel warm, no adjustment to the ink will solve the problem.

Potential issues & solutions

Potential issue
The ink is not drying properly.
Recommended solution

Incorporate faster drying solvents and increase air circulation.

Potential issue
Solvents are becoming entrapped.
Recommended solution

Introduce faster drying solvents and enhance airflow.

Potential issue
The film's pretreatment level is insufficient.
Recommended solution

Evaluate the film's pretreatment and its age. Utilize inline corona treatment.

Potential issue
Ink drying is occurring too slowly.
Recommended solution

Boost the dryer's performance. Employ a faster drying solvent. Decrease the printing speed.

Potential issue
Excessive rewind pressure on the web.
Recommended solution

Reduce the web tension.

Potential issue
The ink or top lacquer is soft or has a low melting point.
Recommended solution

Reformulate the ink or lacquer.

Potential issue
The web is rewound while still too warm.
Recommended solution

Check chill rolls functionality.

Potential issue
Moisture condensation is forming on the chill roll.
Recommended solution

Reset chill rolls to a temperature above the dew point to eliminate moisture.

Potential issue
The ink or varnish is excessively plasticized.
Recommended solution

Reformulate the ink or varnish. Add an anti block agent.

What you see:

Α visible ink mist in non printing areas, which also leads to an increased colour density in the unprinting areas.

Hazing is a doctor blade and cylinder surface problem. Ink that should have been wiped clear of the cylinder land areas is carried through to the substrate, so look at how the blade is meeting the cylinder before you look at the ink. 

hazing with errors image
With Error
hazing correct image
Without Error

Start here:

Check the blade setting and parallelism across the full cylinder width. Note that both a rough cylinder and an over polished one cause hazing, so confirm the surface condition before deciding to polish.

Potential issues & solutions

Potential issue
Improper doctor blade wipe.
Recommended solution

Inspect and readjust the doctor blade settings.

Potential issue
The cylinder surface is slightly rough.
Recommended solution

Polish the cylinder.

Potential issue
The cylinder has been over polished.
Recommended solution

Cylinders that are excessively smooth result in reduced lubrication between the doctor blade and the cylinder, leading to friction. Re polish or replace cylinders with the appropriate roughness.

Potential issue
Poor chrome quality on the cylinder.
Recommended solution

Remake the cylinder.

Potential issue
Ink viscosity is excessively high.
Recommended solution

An overly high ink viscosity results in excessive stagnation pressure, which can lift the doctor blade bevel. Verify and reduce the viscosity.

Potential issue
There is an excessive amount of retarder in the ink.
Recommended solution

Minimize the retarder content in the ink as much as possible.

Potential issue
The cylinder is unbalanced.
Recommended solution

Balance the cylinder.

Potential issue
The doctor blade is not parallel.
Recommended solution

Check and adjust the doctor blade's parallelism.

What you see:

Relatively short stripes that appear and disappear randomly on the printed web.

Comets are caused by something passing under the doctor blade. A particle, a nick in the cylinder or a flaw in the blade lifts it momentarily and the ink escapes as a short tail. Because the cause travels, the defect appears and vanishes rather than holding a fixed position. 

comet with error image
With Error
comet correct image
Without Error

Start here:

Filter the ink and clean the blade before touching the cylinder. Most comets are debris, and polishing a cylinder that was never the problem costs you a cylinder.

Potential issues & solutions

Potential issue
The cylinder surface has nicks.
Recommended solution

Lightly polish or replace the cylinder.

Potential issue
The chrome quality is poor or the surface is worn.
Recommended solution

Compare the cylinder against engraver's proofs and inspect for any loose or flaking chrome areas.

Potential issue
Presence of foreign substances in the ink.
Recommended solution

Check for any foreign substances beneath the blade. Clean the blade and filter the ink.

Potential issue
The doctor blade is not clean or is poorly supported.
Recommended solution

Examine doctor bars for cleanliness. Inspect supporting doctor blades for waviness and replace them if needed.

What you see:

Ink bleeds from the printed area into the unprinted area.

Bleeding is a trapping problem between colours. The first ink down has not dried enough to accept the next, so the second colour redissolves it and carries it beyond the printed edge. Work on the drying of the first station before you touch the second.

bleeding with error image
With Error
bleeding correct image
Without Error

Start here:

Confirm the first colour is fully dry before the web reaches the next station. Raise web temperature and air velocity at that station first, and only then adjust the solvent blend of the following colour.

Potential issues & solutions

Potential issue
Inadequate drying.
Recommended solution

Elevate the web temperature and verify air velocity. Ensure that the initial ink applied is properly dried.

Potential issue
The ink is drying too slowly.
Recommended solution

Decrease the viscosity of the first applied ink and/or thin it with a faster drying solvent. Increase the viscosity of the second color and utilize a lean solvent blend that will not adversely affect the first color.

Potential issue
The ink is incorrect.
Recommended solution

Reformulate or substitute the ink.

Potential issue
The doctor blade setting is too flat.
Recommended solution

Inspect the doctor blade angle and adjust it if required.

What you see:

A dotted or marbled printed image across the solid printing area, with weak ink strength and grainy large format printing.

Mottling points to inconsistent ink transfer out of the cells. Viscosity is the usual cause and it fails in both directions, so measure it rather than assuming which way it has drifted.

ink mottling with error image
With Error
ink mottling correct image
Without Error

Start here:

Measure viscosity against the job standard rather than adjusting by eye. If the ink or the substrate has come straight from a cold store, let both reach room temperature before you judge anything else.

Potential issues & solutions

Potential issue
Ink viscosity is too low.
Recommended solution

Increase ink viscosity.

Potential issue
Ink viscosity is too high.
Recommended solution

Reduce ink viscosity.

Potential issue
Cylinder is too deep.
Recommended solution

Re-etch or replace cylinder.

Potential issue
Press speed is too low.
Recommended solution

Increase press speed.

Potential issue
Press returned ink is unusable.
Recommended solution

Increase resin solids. Use fresh ink.

Potential issue
Ink or substrate is too cold.
Recommended solution

Vary temperature of ink and substrate. Allow to warm to room temperature.

Potential issue
The doctor blade pressure is either too high or too low.
Recommended solution

Adapt to the doctor blade pressure accordingly.

What you see:

The ink is drying inside the cylinder cells, so the cells no longer fill or release correctly and the print weakens or breaks up.

This is a drying-speed problem at the cylinder rather than in the oven. The ink is losing solvent before it reaches the substrate, either because it is formulated too fast, or because air movement around the station is accelerating evaporation. 

ink drying with error image
With Error
ink drying correct image
Without Error

Start here:

Look for air movement across the station before changing the ink. A dryer exhausting towards the cylinder, or an open door, will dry cells faster than any solvent adjustment can compensate for.

Potential issues & solutions

Potential issue
Ink viscosity is excessively high.
Recommended solution

Decrease the ink's viscosity.

Potential issue
The ink is drying too rapidly.
Recommended solution

Incorporate slower drying solvents.

Potential issue
Air drafts are impacting the cylinder.
Recommended solution

Eliminate all air drafts.

Potential issue
Poor ink resolubility.
Recommended solution

Utilize an active solvent or reformulate the ink.

Potential issue
The room or ink temperature is too high.
Recommended solution

Condition the ink or the room environment.

Potential issue
Improper doctor blade wipe.
Recommended solution

Inspect, readjust or change the doctor blade.

What you see:

Ink is picked up off the web by the next printing cylinder, removing it from the printed image.

Picking means the ink is still wet when it reaches the following station or the next roll. It is the same root cause as bleeding but shows as removal rather than spread, and the fix sits in drying capacity and web temperature.

ink picking with error image
With Error
ink picking correct image
Without Error

Start here:

Check the idler rolls before adjusting the ink. A tacky roll picks ink off a print that was otherwise dry enough, and it will keep doing so on every job until it is cleaned.

Potential issues & solutions

Potential issue
The ink is drying too slowly.
Recommended solution

Introduce a faster drying solvent.

Potential issue
The oven temperature is insufficient.
Recommended solution

Increase heat and air velocity.

Potential issue
Ink viscosity is excessively high.
Recommended solution

Reduce ink viscosity using thinned extender varnish or solvent.

Potential issue
Idler rolls are dirty or tacky.
Recommended solution

Clean idler rolls.

Potential issue
The web is too warm after the printing units.
Recommended solution

Check the chill rollers and/or decrease the chill roll temperature.

When to escalate to technical support

Work the relevant section above first, as most defects resolve at press. Escalate when:

  • the defect returns on the next job with a different design, ink and substrate combination
  • corrective action on one variable produces a second defect elsewhere in the print
  • adhesion or bond strength is involved and the product is destined for lamination, retort or food contact
  • the fault appears across more than one press in the plant 

Our technical support is here to help

DF Inks' technical service team works on site with converters across Europe, the Middle East and Africa, supported by our own laboratories and production facilities in Greece, Romania and Nigeria. We formulate the ink, so we can customize it for converters not just recommend a workaround. 

FAQs about rotogravure printing defects

The most common causes are an ink chemistry that does not match the substrate, inadequate surface treatment, insufficient drying, and contamination on the film surface. Check the film's treatment level first, corona treatment decays during storage, and an aged film will fail a tape test regardless of ink performance.

Hazing is a fine ink mist left in the non printing areas, which also raises colour density in the unprinted areas. It means the doctor blade is not wiping the cylinder cleanly, through blade setting, blade parallelism, cylinder surface roughness or chrome quality, or because high ink viscosity is lifting the blade bevel.

Comets are short stripes that come and go at random, caused by debris or a nick passing under the blade. Hazing is a continuous mist across the non printing areas, caused by the blade failing to wipe the cylinder properly. Comets travel, hazing does not.

Many can be corrected in-run, particularly viscosity, doctor blade pressure, oven temperature and air velocity. Defects rooted in the cylinder, the chrome surface or the substrate batch require a stop. Change one variable at a time and record the result, simultaneous adjustments make the cause impossible to identify.